Inadequate Flow Rate
Issue:
The cleaning cycle is inefficient because the flow rate is below required specifications.
Causes:
.Pump undersized or experiencing wear
.Clogged piping or restrictions in the CIP line
.Wrong spray ball selection (flow rate mismatch)
Solution:
.Match pump specifications with the spray ball’s required flow rate
.Inspect and clean the CIP lines regularly
.Replace with a spray ball model designed for your flow range